content is empty!
Availability: | |
---|---|
HD-G826
Haida
Electro-Dynamic Shaker Table
Introduction:
Electro-Dynamic Shaker Table is used to determining the design and manufacture of machines and components that are subjected to external vibration tables or vibrations generated by themselves during transportation and use without damage, and to achieve their performance and reliability for a predetermined life.
Application:
Vibration Test Table is suitable for vibration testing of samples in laboratories and production lines of automotive parts, electronic components, components, medicine, food, furniture, gifts, ceramics, packaging, etc. Such as environmental acceptance test, quality identification test, reliability identification test, endurance test, vibration simulation analysis, material property test, fatigue test, vibration prevention improvement, etc. Simulate the vibration environment that the product is subjected to during manufacturing, assembly, transportation, and use to assess the vibration resistance, reliability, and integrity of its structure.
Features:
Sine wave, frequency modulation, frequency sweep, programmable, frequency doubling, logarithm, maximum acceleration, amplitude modulation, time control, full function computer control, simple fixed acceleration/fixed amplitude
How to use
1, the control manual to complete the procedure
2, such as Operation error so that can not work, you can use the recovery method of the steps of the input, and then set a single group or other running steps.
3, before use to press the external start switch, appears COO namely lets go, opens the key.
4, Taiwan Body:
1 The table body foot sleeve as far as possible fixed
2 power supply on/work in the output line can not be unplugged
3 Place the level as far as possible
4 components can be changed, the line should not be changed or from the connection.
5 The Taiwan body must not be all or part of the reorganization, only according to specifications for a single component and with the original confirmation password.
composition of electrodynamic shake vibration tester
Vibration test bench, power amplify, cooling fan,Slip table,vertical expander
Electro-Dynamic Shaker Table
Introduction:
Electro-Dynamic Shaker Table is used to determining the design and manufacture of machines and components that are subjected to external vibration tables or vibrations generated by themselves during transportation and use without damage, and to achieve their performance and reliability for a predetermined life.
Application:
Vibration Test Table is suitable for vibration testing of samples in laboratories and production lines of automotive parts, electronic components, components, medicine, food, furniture, gifts, ceramics, packaging, etc. Such as environmental acceptance test, quality identification test, reliability identification test, endurance test, vibration simulation analysis, material property test, fatigue test, vibration prevention improvement, etc. Simulate the vibration environment that the product is subjected to during manufacturing, assembly, transportation, and use to assess the vibration resistance, reliability, and integrity of its structure.
Features:
Sine wave, frequency modulation, frequency sweep, programmable, frequency doubling, logarithm, maximum acceleration, amplitude modulation, time control, full function computer control, simple fixed acceleration/fixed amplitude
How to use
1, the control manual to complete the procedure
2, such as Operation error so that can not work, you can use the recovery method of the steps of the input, and then set a single group or other running steps.
3, before use to press the external start switch, appears COO namely lets go, opens the key.
4, Taiwan Body:
1 The table body foot sleeve as far as possible fixed
2 power supply on/work in the output line can not be unplugged
3 Place the level as far as possible
4 components can be changed, the line should not be changed or from the connection.
5 The Taiwan body must not be all or part of the reorganization, only according to specifications for a single component and with the original confirmation password.
composition of electrodynamic shake vibration tester
Vibration test bench, power amplify, cooling fan,Slip table,vertical expander
Parameters of electrodynamic vibration tester
Axial vibration isolation frequency | <3 Hz | |
Max. Payload | 500 kg | |
Magnetic flux leakage | ≤1 mT | |
Dimensions (L×W×H, unpacked) | 1,330x860x1,250 mm | |
Weight (unpacked) | 2,500 kg | |
Installation | Rubber mat (anchor bolts required) | |
Power Amplifier (Model# VSA-H323A) | ||
Amplifier output | 30 kVA | |
SNR | >65 dB | |
Rated output voltage | 120 Vrms | |
Amplifier efficiency | > 90% | |
Dimensions (L×W×H, unpacked) | 800x900x2,100 mm | |
Weight (unpacked) | 500 kg | |
Blower (Model# PBL-W30) | ||
Air volume | 0.46 m3/s | |
Power | 7.5 kW | |
Air duct diameter | 200 mm | |
Air pressure | 8.8kPa | |
Installation | Able to connect to ceiling (up to two 90 degree bends), max 20’ run | |
Horizontal Slip Table (Model# 30ST-600M) | ||
Dimensions | 600x600 mm | |
Thickness | 45 mm | |
Frequency limit | 2,000 Hz | |
Effective mass | 54 kg | |
Note: 1. High pressure oil-film bearing is used for better uniformity. | ||
Vibration Controller and Accelerometer | ||
Vibration Controller VT-9008-4 | 4 Channel Vibration Controller with Sine and Self Calibration. | |
Accelerometer EA-YD-181 | 100mV/g, Range: 50g, Working Freq.: 1-10kHz, Weight: 11gram, with 10ft low noise cable | |
Other supported functions/accessories | ||
Environmental chambers | Supported | |
Mobile devices | Customizable | |
Insulation boards | Customizable | |
Fixture | Customizable | |
Working environment of the system | ||
Temperature range | 0-40℃ | |
Humidity range | 0~90% , no condensation | |
Power requirements | 380V/3ph/50Hz, 40kVA | |
Compressed air pressure | 0.6 Mpa |
The table parameters is for the company Standard Model parameters, we support customer customization parameters
Parameters of electrodynamic vibration tester
Axial vibration isolation frequency | <3 Hz | |
Max. Payload | 500 kg | |
Magnetic flux leakage | ≤1 mT | |
Dimensions (L×W×H, unpacked) | 1,330x860x1,250 mm | |
Weight (unpacked) | 2,500 kg | |
Installation | Rubber mat (anchor bolts required) | |
Power Amplifier (Model# VSA-H323A) | ||
Amplifier output | 30 kVA | |
SNR | >65 dB | |
Rated output voltage | 120 Vrms | |
Amplifier efficiency | > 90% | |
Dimensions (L×W×H, unpacked) | 800x900x2,100 mm | |
Weight (unpacked) | 500 kg | |
Blower (Model# PBL-W30) | ||
Air volume | 0.46 m3/s | |
Power | 7.5 kW | |
Air duct diameter | 200 mm | |
Air pressure | 8.8kPa | |
Installation | Able to connect to ceiling (up to two 90 degree bends), max 20’ run | |
Horizontal Slip Table (Model# 30ST-600M) | ||
Dimensions | 600x600 mm | |
Thickness | 45 mm | |
Frequency limit | 2,000 Hz | |
Effective mass | 54 kg | |
Note: 1. High pressure oil-film bearing is used for better uniformity. | ||
Vibration Controller and Accelerometer | ||
Vibration Controller VT-9008-4 | 4 Channel Vibration Controller with Sine and Self Calibration. | |
Accelerometer EA-YD-181 | 100mV/g, Range: 50g, Working Freq.: 1-10kHz, Weight: 11gram, with 10ft low noise cable | |
Other supported functions/accessories | ||
Environmental chambers | Supported | |
Mobile devices | Customizable | |
Insulation boards | Customizable | |
Fixture | Customizable | |
Working environment of the system | ||
Temperature range | 0-40℃ | |
Humidity range | 0~90% , no condensation | |
Power requirements | 380V/3ph/50Hz, 40kVA | |
Compressed air pressure | 0.6 Mpa |
The table parameters is for the company Standard Model parameters, we support customer customization parameters
Vibration Test Equipment Video
Vibration Test Equipment Video